Saturday, September 14, 2019
Computional Fluid Dynamics Through a Pipe
Table of Contents INTRODUCTION3 Method:3 Part 23 Part 33 Part 44 Part 54 RESULTS4 Part 14 Part 26 Part 36 Part 46 Part 5:6 DISCUSSION7 CONCLUSION7 REFERENCES7 INTRODUCTION The main objective of this assignment is to simulate a 3-D air flow in a pipe using Ansys CFX. The pipe was simulated under specific conditions. These conditions are air temperature to be 25? C (degrees Celsius), one atmospheric reference pressure, no heat transfer and laminar flow. The results from the simulation of laminar flow in the pipe were compared with the theoretical ones.Also the mesh was refined in the simulation to see if it is possible to get more accurate results using grid convergence analysis. Method: The pipe used in the simulation has dimensions of a 0. 5m axial length and a radial diameter of 12mm. The air entering the pipe, inlet velocity, is set to 0. 4 m/s at a temperature of 25? C and one atmospheric pressure. No slip condition was set on the pipe walls. The outlet of pipe was set to zero gau ge average static pressure. In CFX a mesh was formed on the pipe with a default mesh spacing (element size) of 2mm.Figure (1) and (2) shows the setup of the model before simulation was preformed Figure 1: Mesh without Inflation Figure 1: Mesh without Inflation Figure 2: Mesh with Inflation Part 2 Calculating the pressure drop ? p=fLD? Ub22Equation (1) Calculating Reynolds number Re=UbD/? Equation (2) Friction Factorf=64/ReEquation (3) The results were calculated using excel, and plotted in Figure (3). Part 3 Estimating the entrance pipe length Le: Le/D=0. 06ReEquation (4) Having Re=UbD/? Equation (3) The simulated results of velocity vs. axial length were plotted in Figure (5).From the graph the Le (entrance pipe length) was determined by estimating the point in the x-axis where the curve is straight horizontal line. Part 4 Comparison of the radial distribution of the axial velocity in the fully developed region in the simulated model against the following analytical equation: UUmax = 1-rr02 Equation (5) The results were calculated using excel, and plotted in Figure (4). Part 5 The simulation was performed three times, each time with a different grid setting. The numbers of nodes were 121156,215875 and 312647 for the 1st, 2nd and 3rd simulation.RESULTS Part 1 Figure 3: Pressure Distribution vs. Axial Length Figure 3: Pressure Distribution vs. Axial Length Figure 4: Axial Velocity vs. Radial Diameter Figure 5: Velocity vs. Axial Distance Part 2 Having: Dynamic viscosity ? = 1. 835Ãâ"10-5 kg/ms and Density ? = 1. 184 kg/m3 Reynolds Number Re=UbD? == 261. 58 Friction Factorf=64Re== 0. 244667 ?p=0. 965691 Pa From the simulation the pressure estimated at the inlet is ? p=0. 96562 Pa (0. 95295-0. 965691)/0. 965691*100 = 1. 080 % Part 3 Having Re=UbD? =261. 58 The entrance pipe length Le: Le=0. 06Re*D = 0. 188 mFrom the graph in Figure (3) the Le is estimated to be ~ 0. 166667 ((0. 166667-0. 188)/0. 188)*100 = 11. 73% Part 4 From the graph in Figure 2 the theoretic al velocity at the center of the pipe is estimated to be 0. 8 m/s. From the simulation the velocity at the center of the pipe is estimated to be 0. 660406 m/s. ((0. 688179-0. 8)/0. 8)*100= 13. 98% Part 5: Table 1: Percentage Error for Each Simulation Number of Nodes| Axial Velocity % error (%)| Pressure % error (%) | 120000 Simulated I| 13. 98| 1. 31| 215000 Simulated II| 12. 42| 2. 24| 312000 Simulated III| 12. 38| 2. 28|Figure 6: Percentage Error vs. Number of Nodes Figure 6: Percentage Error vs. Number of Nodes The percentage error for the axial velocity results from the 1st, 2nd and 3rd simulation were calculated and plotted in Figure (6), as well as the pressure result along the pipe. Table (1) shows the axial velocity and pressure percentage error for each simulation. DISCUSSION After the simulation was successfully done on Ansys CFX and the simulated results were compared with theoretical results, it was found that the simulated results have slight deviation from theoretical ones. In PART 2, he pressure in the simulated result differed by the theoretical by a 1. 080%, for 1st simulation. In PART 3, the simulated results for entrance pipe length, Le, differed from the theoretical results by 11. 73%. In PART 4, Figure (4), the simulated velocity curve is less accurate than that of the theoretical. In PART 5, meshing refinements and inflation were done to the simulation in order to getting better results. Figures (6) show with more nodes and inflation the accuracy of the results increases. Increasing the nodes gradually was found to be an advantage where higher or more accurate results were obtained.This is noted in grid convergence graph, Figure (6), as the number of nodes increase the pressure percentage error is converging to 2% while for velocity percentage error is converging to 12%. On the other hand, the percentage error increased with the increase of the number of nodes while the velocity error decreased with the increase of number of nodes. In Par t 2 the percentage error for pressure drop is 1. 080%, for 1st simulation. But when trying to increase the accuracy of the simulated velocity result by refining the meshing and adding nodes the pressure drop percentage error increases, as shown in figure (6).This is due to that Darcy-Weisbach equation, equation (1), assumes constant developed flow all along the pipe where in the simulated results the flow is observed to become developed father down the pipe from the inlet. This is assumed to change the pressure distribution along the pipe. CONCLUSION More nodes used in meshing will produce more accurate and precise results, as shown in Figure (6). Also the meshing plays a vital rule on the sensitivity of results in terms of the accuracy of these results. REFERENCES [1]Fluid Mechanics Frank M. White Sixth edition. 2006
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.